Full flow and side stream filtration are the two most common methods that are used to directly protect the heat exchangers and chillers.
Side stream filter for cooling tower design.
Side stream filtration systems continuously filter a portion of the cooling water to remove suspended solids organics and silt particles reducing the likelihood of fouling and biological growth which in turn helps to control other issues in the system such as scaling and corrosion.
Side stream filtration on the other hand continuously filters a percentage.
According to cooling tower manufactures side stream filtration is the best practice for maintaining a clean safe and efficient operation.
Many times the filtered water is piped into a header system that.
Side stream filtration for cooling towers 2x1500 m3 hr more info.
Forsta cooling tower filters have a compact design allowing for easy installation in existing pipelines.
Forsta side stream filters and full flow cooling tower filters keep water clean protecting heat exchangers chillers condensers spray nozzles and pumps all while significantly reducing energy consumption.
Cooling tower filtration system.
For example if the total flow of a system is 1 200.
Uses a filter installed after the cooling tower on the discharge side of the pump.
Because of the modular design the filters can handle up to four times this size.
Modern day cooling tower systems have thus adopted side stream filtration of the water from the cooling tower.
The filtered water should be returned to the cooling tower in the areas of lowest flow.
For the cooling tower at building 124 the system volume was determined by the salt test.
Full flow filtration utilizes a filter installed after the cooling tower on the discharge side of the pump.
Vasudev water solution as side stream filters manufacturer side stream filter for cooling tower and cooling tower filter system from ankleswar vadodara gujarat vapi daman silvassa dahej umargam bharuch to ahamdabad.
It is typical to size the side stream filter to continuously filter the cooling tower basin water at a rate equivalent to 10 of the total circulation flow rate.
With an operating capacity of 70 gpm per filter the ct70 is ideal for up to 800 ton towers.
The basin water inventory may only be filtered and or side stream filters may be employed at the discharge of the cw recirculation pumps.
Www inexa es info inexa es 34 928 457 081.
Various schemes can be implemented.
Full flow and side stream filtration.
Properly sizing side stream filters for cooling towers is crucial to obtain optimal filter performance.
A filter based upon system volume would be smaller and thus have a lower initial capital cost.